FREE SHIPPING ON ALL FIREPLACE DOORS - CHECK OUT OUR PROMOTIONS
100% secure
online shopping
FREE SHIPPING
On all orders!  
Continental US
Phone Hours
Mon - Fri: 9:00am - 6:00pm EST

Metal-Fab 8" Temp/Guard Pitched Ceiling Plate 8TGPCP8

Starting at:
$102.39
Short description:

Free Shipping on All Orders Continental United States!  Ships Out Within 1-2 Weeks

Available
+

The Metal-Fab 8" Temp/Guard Pitched Ceiling Plate 8/12 Pitch 8TGPCP8 is an essential component designed to be utilized when the TGAS supports the chimney pipe. This specialized plate serves a crucial function by covering any gap between the chimney pipe and the ceiling in installations with varying pitches.

One of the critical features of this ceiling plate is its oval interior diameter (I.D.), strategically crafted to cover and bridge any gaps in the chimney pipe and the ceiling seamlessly. This enhances the installation's aesthetic appeal and ensures a tight and secure fit, minimizing the chances of heat or gases escaping into the surrounding areas.

It's worth noting that the Metal-Fab 8" Temp/Guard Pitched Ceiling Plate comes with specific pitch designations, in this case, 8/12 Pitch. This indicates that the plate is tailored to accommodate ceiling pitches within this range, providing a versatile solution for various installation scenarios. It's essential to choose the appropriate plate that corresponds with the specific pitch of the ceiling where it will be installed.

Moreover, the interior diameter of the plate is sized to fit over the trim sleeve (TGTS), adding another layer of compatibility and ensuring seamless integration with other components of the Temp/Guard system. This thoughtful design not only simplifies the installation process but also contributes to the overall effectiveness and output of the chimney system.

In summary, the Metal-Fab 8" Temp/Guard Pitched Ceiling Plate 8/12 Pitch 8TGPCP8 is a reliable and functional component that plays a crucial role in ensuring chimney systems' proper installation and performance. It is an invaluable addition to any installation where a safe and visually pleasing connection between the chimney pipe and the ceiling is required because of its well-thought-out design, which includes the oval I.D. and compatibility with the TGTS.


Features:

  • Approved for most fuel types
  • Made of galvalume
  • UL Listed for 1 1/2" clearance to combustibles on 6", 7", and 8" Diameters
  • Painted in black

Specification:

  • Inner Diameter: 8-Inch
  • Material: Galvanized
  • Fuel Type: Coal, Gas, Oil, Wood
  • UL Listing Number: UL 103 HT
  • Product Type: Pitched Ceiling Plate

Downloads:


Class A Chimney Pipe

Class A Chimney Pipe is a critical component of any efficient and safe residential or commercial heating system. These pipes are designed to vent smoke, gases, and combustion byproducts from wood-burning stoves, fireplaces, furnaces, and other heating appliances, offering a secure and insulated pathway for exhaust to exit the building while preventing heat transfer to combustible materials. Class A Chimney Pipes are known for their durability, safety features, and versatility, making them an essential part of any well-functioning chimney system.

Key Features

Double-Wall Construction: Class A Chimney Pipes feature a double-wall design with an inner stainless steel liner and an outer layer of galvanized or stainless steel. This construction provides excellent insulation, reducing the risk of overheating and maintaining safe temperatures on the exterior.

Insulation: The insulation between the inner and outer walls minimizes heat transfer, allowing the pipe to pass through walls, ceilings, and attics without causing nearby materials to catch fire.

Easy Installation: Class A Chimney Pipes come with a twist-lock or snap-lock system, ensuring a straightforward and secure installation process. Many also offer adjustable lengths to accommodate various installation requirements.

Weather Resistance: These pipes are built to withstand harsh weather conditions, including rain, snow, and wind. They often feature a rain cap or spark arrestor to prevent water and debris from entering the chimney.

Versatility: Class A Chimney Pipes are suitable for both new installations and retrofitting existing chimneys. They can be used with a variety of heating appliances, including wood stoves, pellet stoves, gas fireplaces, and oil furnaces.

Frequently Asked Questions

Q: What is the difference between Class A and Class B chimney pipes?
A: Class A chimney pipes are designed for exterior use and are insulated to prevent heat transfer. Class B pipes are for interior use, and they do not require insulation because they rely on the building's structure for heat protection.

Q: Can I install a Class A chimney pipe myself?
A: While some homeowners may have the skills to install Class A chimney pipes, it is recommended to hire a professional chimney technician to ensure proper installation, safety, and compliance with local building codes.

Q: How often should I clean and maintain my Class A chimney pipe?
A: Regular maintenance is crucial to prevent creosote buildup and ensure proper ventilation. It's advisable to have your chimney inspected and cleaned annually by a certified chimney sweep.

Q: Can I use Class A chimney pipes with a wood-burning fireplace or stove?
A: Yes, Class A chimney pipes are commonly used with wood-burning appliances. Ensure that the pipe's diameter matches the appliance's outlet and that it complies with local codes and regulations.

Q: Are there specific clearances I need to maintain with Class A chimney pipes?
A: Yes, each manufacturer provides guidelines for clearance distances from combustible materials such as walls, ceilings, and roofs. These distances can vary, so it's essential to follow the manufacturer's recommendations and local building codes.

Class A Chimney Pipes are an integral part of your heating system's safety and efficiency. Choosing the right pipe and ensuring proper installation and maintenance can help you enjoy a warm and comfortable living space while safeguarding against potential fire hazards.

CERTIFICATE OF WARRANTY

Limited Lifetime Warranty

 

The Metal-Fab TEMP GUARD factory-built chimneys, when installed according to manufacturer's instructions, as prescribed by Underwriters Laboratories Standard 103HT, and when properly and regularly cleaned and maintained as set forth below, are warranted by Metal-Fab Inc. under normal residential use against defects in material or workmanship of the product for parts only for as long as the original consumer owns the chimney system. During the first ten years of the warranty, Metal-Fab will provide replacement chimney lengths at no charge. During the balance of the warranty, Metal-Fab will provide replacement chimney lengths at 50% of the current retail price in effect at the time of the warranty claim. The defective part(s) must be returned with all transportation charges prepaid by the owner to the Customer Service Department, Metal-Fab Inc., 3025 May Avenue, Wichita, Kansas 67213. Metal-Fab Inc. will in turn ship the repaired or replacement part to the owner, freight collect, with the owner to be responsible for all freight charges. This warranty does not cover any labor or other service charges incurred by the owner, or any parts not manufactured by Metal-Fab Inc.

It is the OWNER'S RESPONSIBILITY to establish:

  1. the date of the original installation of the product;

  2. the name of the original purchaser;

  3. the name of the installer;

  4. that the product was installed according to manufacturer's instructions; and

  5. that the product was properly cleaned and serviced once each year by a licensed chimney sweep.

 

DISCLAIMERS AND EXCLUSIONS

The following shall be applicable to those products of Metal-Fab Inc. described above:

  1. The warranty described hereinabove shall be IN LIEU of any other warranty, express or implied. Except as set out hereinabove, there are NO other warranties and any statutory or implied warranty of MERCHANTABILITY or fitness for a particular purpose is EXCLUDED from this transaction and shall not apply.

  2. The sole and exclusive remedy against Metal-Fab Inc. shall be for the repair or replacement of defective parts as provided hereinabove. NO OTHER REMEDY (including, but not limited to, incidental or consequential damages for lost profits, lost sales, injury to person or property, or any other incidental or consequential loss) shall be available. The sole purpose of the stipulated exclusive remedy provided for herein, shall be the repair and replacement of defective parts in the manner provided hereinabove. This exclusive remedy shall not be deemed to have failed of its essential purpose so long as Metal-Fab Inc. is willing and able to repair or replace defective parts in the prescribed manner.

  3. The owner shall not be required to deliver a defective part to Metal-Fab Inc. if:

    1. The part was destroyed as a result of its defect or any defect in any part covered in this warranty; and

    2. Metal-Fab Inc. is reasonably satisfied that the part was defective at the time of sale.

      If both of these conditions are met to Metal-Fab Inc.'s satisfaction, it will replace the part in the same manner provided herein as if the purchaser had delivered it to Metal-Fab Inc.

  4. The owner acknowledges that no oral statements purporting to be warranties, representations, or guarantees of any kind about any product of Metal-Fab Inc. have been made to owner by Metal-Fab Inc. by the original purchaser if different from the owner, or by its dealer which in any way expands, alters or modifies the terms of the warranty set out herein. Any such statements do not constitute warranties, shall not be relied on by the owner, and are not part of the contract of sale. This writing constitutes a complete and exclusive statement of the terms of any warranty, express or implied, of Metal-Fab Inc.

  5. There is NO WARRANTY for any defective part of a Metal-Fab product which has been removed from its original installation site or which, in the judgment of Metal-Fab Inc., arises from misuse, mishandling, neglect, chimney fire, flood, lighting, corrosive atmosphere, improper installation of the product, improper servicing of the product, unauthorized modification of the product, improper fuel supply to the product, or the failure of the installer to properly install or service the product as is set out in the installation instructions.

 

©Metal-Fab, Inc. Form No. L799 –9/03

7250

No posts found

Write a review

Click on the Add New button below to submit a question about this product. Please ONLY submit product questions. For all other inquiries, please contact us at 1-888-986-1535.

Last updated on May 7th 2024.

 

 

Share on Social Media!
 Share on Facebook Share on Twitter Save this product on Pintrest!