DuraVent 6" DuraPlus Attic Insulation Shield Kit

Write a review
$80591
$1,00737 -20%
Available
+
Compare

Free Shipping on All Orders Continental United States!  Free Shipping | Ships Within 1-2 Weeks

A complete solution, the DuraVent 6" DuraPlus Attic Insulation Shield Kit makes it easier to install a chimney system that is specifically made to install a chimney system in attic effectively and safely. This kit contains several necessary parts to guarantee your 6" DuraPlus system is connected securely and by the code when used in an attic. Essential parts that come with this kit are:

1. 6" DuraPlus Chimney Cap: The chimney cap acts as a barrier to keep debris, weather, and other outside elements out of the chimney while allowing for sufficient ventilation.

2. 6" DuraPlus Storm Collar: The storm collar strengthens the chimney's resistance to bad weather by creating a watertight seal around it and offering extra security.

3. 6" DuraPlus Attic Insulation Shield: The attic insulation shield prevents heat transfer to explosive objects in the attic, guaranteeing safety and adherence to insulation regulations.

4. 6" DuraPlus Flashing: The flashing acts as a weatherproof barrier to stop water from penetrating the area around the chimney, enhancing overall waterproofing and maintaining the structural integrity of the chimney system.

5. 6" DuraPlus Ceiling Support Box: Besides facilitating the chimney system's passage through ceilings and providing stability and structural support, the ceiling support box ensures a secure connection and adherence to safety guidelines.

The DuraVent 6" DuraPlus Attic Insulation Shield Kit is a specialized solution for installing a chimney safely. DuraVent's kit, which combines supporting, insulating, and protective components, demonstrates its dedication to offering a dependable and legal chimney system that works to install a chimney system in attic.


Features:

  • Triple-wall chimney
  • Clean, smooth exterior finish
  • 2" clearance to combustibles
  • Outer diameter is 4" larger than inner diameter
  • Free-floating inner 430-alloy liner maintains structural integrity in chimney fires
  • For uses with wood stoves, fireplaces, furnaces, boilers, stoves, ranges, water heaters, or other appliances fueled by wood, oil, coal, or gas

Specifications:

  • Size: 6" Inner Diameter
  • Material: Stainless Steel | Aluminum | Galvanized
  • Fuel Type: Coal, Oil, Wood, Gas
  • UL Listed: UL-103-HT
  • Vent Construction: Triple Wall
  • Type: Kit

Downloads:


How to Install DuraPlus Chimney Pipe Kits using Attic Insulation Shield?

When it comes to installing a ceiling-supported chimney pipe, ensuring a safe and efficient setup is essential for both performance and peace of mind. With a carefully planned approach, you can achieve a reliable installation that enhances the safety, efficiency, and appearance of your home. Follow this step-by-step guide to make the most of your chimney installation. The DuraPlus Attic Insulation Shield Kit is available in 6-Inches, 7-Inches and 8-Inches.

Why Choose Ceiling-Supported Chimney Pipe Installation?

  1. Safety-First Design: Ceiling-supported chimney pipes are engineered to meet the highest safety standards. By providing the proper clearances and utilizing support boxes and insulation shields, you create a secure environment that reduces fire hazards.
  2. Flexibility Across Multi-Story Homes: Whether you have a two-story home or a multi-story building, this installation method adapts to your needs. From firestop radiation shields to attic insulation shields, this solution offers comprehensive safety for every floor.
  3. Aesthetic and Functional Enhancements: With optional trim kits, including brass finishes, you can elevate the look of your installation. Combine safety and style for a professional and polished appearance.

Step-by-Step Installation Guide

  1. Place Your Appliance: Position the appliance according to the manufacturer’s instructions, ensuring the flue outlet collar aligns between the rafters or joists above. Proper placement is crucial for maximum efficiency and minimal structural impact.
  2. Frame the Support Opening: Use a plumb bob to mark the center of the appliance’s flue outlet on the ceiling. Cut a square or round hole based on the support box type, and frame a level opening accordingly.
  3. Install the Support Box: Insert the support box into the framed opening, making sure it extends at least 2 inches below the ceiling. Secure it with two 8-penny nails per side and attach trim frames using wood screws. This sturdy attachment is the backbone of a secure installation, ensuring stability across floors.
  4. Frame the Openings: Continue framing the openings on each ceiling or floor above the support box, accommodating firestop and attic insulation shields. Using a plumb bob ensures alignment and maintains the required clearances. This step is crucial for preserving safety as the chimney rises through your home.
  5. Cut the Roof Opening: Cut an opening in the roof, ensuring it’s at least 4 inches larger than the chimney’s diameter for a 2-inch clearance all around. This clearance allows proper airflow and prevents heat buildup, minimizing risks. If the chimney is between rafters spaced 16 inches apart, Close Clearance Shields (from DuraVent) can be used, avoiding structural reframing and maintaining the necessary clearances.
  6. Install Firestop Radiation Shield: Whether it’s a two-story or multi-story building, proper installation of the firestop radiation shield is essential. This shield protects your home by maintaining safe clearances between floors. 
  7. Assemble the Chimney Sections: Begin assembly by lowering the first chimney section into the support box. Twist-lock it onto the starter section, ensuring a tight and secure fit. While sheet metal screws are optional, they can provide extra reinforcement if needed. This assembly forms the foundation of your chimney system.
  8. Install the Attic Insulation Shield: This shield prevents insulation and debris from coming into contact with the chimney as it passes through the attic. With a height of 14 inches, it’s designed for most attic spaces. Where it doesn’t fit, a square support box up to 36 inches can serve as an alternative, ensuring you always have the right option for your home.
  9. Attach the Flashing: For both new and existing roofs, install the flashing to prevent leaks and weather damage. Maintain a 2-inch clearance around the chimney and secure the flashing without penetrating the chimney pipe. This step not only ensures durability but also enhances the overall appearance of your chimney system.
  10. Finish the Top: Seal the chimney with a non-hardening waterproof sealant before attaching the storm collar and chimney cap. This final layer of protection prevents water intrusion and maintains the chimney’s integrity. If the chimney extends more than 4 feet above the roof, use an extended roof bracket for extra support.
  11. Enclosures for Safety and Aesthetics: In occupied spaces or closets, enclose the chimney with at least a 2-inch clearance from combustible surfaces. Interior enclosures, framed with sheetrock or plywood, offer a finished look while ensuring safety. Wall straps can be used to maintain the required air space, adding an extra layer of protection.

Choosing a ceiling-supported chimney pipe system is not just about compliance; it's about enhancing your home’s safety, efficiency, and aesthetic appeal. By following these detailed steps and using high-quality materials, you’ll create a reliable and lasting chimney system that stands up to the elements while seamlessly integrating into your home. Invest in a safe and efficient chimney installation today for a comfortable, worry-free living environment!

Manufacturer's Warranty

DURAVENT LIMITED LIFETIME WARRANTY
DuraVent, Inc. (“DuraVent”) provides this limited lifetime warranty for all of its products with the exception of Ventinox® (lifetime), and PolyPro® (ten years). Subject to the limitations set forth below, DuraVent warrants that its products will be free from defects in material or manufacturing, if properly installed, maintained and used. DuraVent products are fully warranted if installed only by a professional installer. This Warranty is transferable from the original homeowner to the buyer of the home. This warranty does not cover normal wear and tear, smoke damage or damage caused by chimney fires, acts of God, or any product that was: (1) purchased other than from an authorized DuraVent dealer, retailer or distributor; (2) modified or altered; (3) improperly serviced, inspected or cleaned; or (4) subject to negligence or any use not in accordance with the installation instructions included with the product as determined by DuraVent. Installation instructions are available online at www.duravent.com under Support/Literature and through our Customer Service Department 800-835-4429 or customerservice@duravent.com. This limited lifetime warranty applies only to parts manufactured by DuraVent.

DuraVent provides the following warranties for its products: One Hundred Percent (100%) MSRP 15 years from the date of purchase, and Fifty Percent (50%) thereafter, except for the following limitations on: all Termination Caps and DuraBlack® are warranted at One Hundred Percent (100%) for five years. All warranty obligations of DuraVent shall be limited to repair or replacement of the defective product pursuant to the terms and conditions applicable to each product line. These remedies shall constitute DuraVent’s sole obligation and sole remedy under this warranty. This warranty provides no cash surrender value. The terms and conditions of this warranty may not be modified, altered or waived by any action, inaction or representation, whether oral or in writing, except upon the express, written authority of an executive officer of DuraVent.

Corn, bio-fuels, driftwood or other wood containing salt, preservative-treated lumber, plastic and household trash or garbage, or wood pellets containing such materials must not be burned in the appliance or fireplace. In case of a chimney fire, the chimney must be inspected and approved by a certified Chimney Sweep before reuse. After each annual inspection, maintenance, and cleaning, the certified Chimney Sweep must fill out and date the appropriate section of the warranty card provided with the chimney liner.

LIMITATIONS ON INTERNET SALES:
Notwithstanding any other terms or conditions of this Limited Lifetime Warranty, DuraVent provides no warranty for the following specific products if such products are not installed by a qualified professional installer: DuraTech®, DuraPlus HTC®, DuraChimney® II, PelletVent Pro®, DirectVent Pro®, FasNSeal®, FasNSeal® W2, FasNSeal® Flex, and PolyPro®, and DuraVent’s relining products including DuraLiner®, DuraFlex® (SW, Pro, 316, 304), and Ventinox®. For purposes of this warranty, a trained professional installer is defined as one of the following: licensed contractors with prior chimney installation experience, CSIA Certified Chimney Sweeps, NFI Certified Specialists, or WETT Certified Professionals.

5
5 out of 5
Reviews: 1
5 stars
100%
4 stars
0%
3 stars
0%
2 stars
0%
1 star
0%
John Jones
5
Comment
This is the best product in the world!
Questions
Products You May Be Interested In
  • Most Popular
  • On Sale
  • Recently Viewed
 
Fast and Reliable Shipping

Free Shipping on ALL Fireplace Doors

Trusted Quality and Expertise

We stand behind every product we sell with expert support and proven performance

Premium Packaging

Your order is packaged to meet the highest standards