The Horizontal DirectVent Pro Vent Kit 46DVA-HCL34 – is the perfect solution for situations where terminating the vent for a direct-vent gas appliance atop a masonry chimney proves challenging or impractical. This innovative kit is now available for use with approved appliances, offering a hassle-free and efficient venting solution.
Designed with versatility in mind, the Horizontal Vent Kit for DV Inserts allows you to vent an approved appliance horizontally through the back of a suitable masonry chimney. This is particularly beneficial in scenarios where traditional vertical venting may not be feasible.
The kit comes complete with essential components to streamline the installation process, ensuring a secure and reliable venting system. Included in the kit are the Co-Linear Termination, Two 10’ Aluminum Flex Lengths (available in both 3x3 or 3x4 configurations), and all the necessary hardware for Flex Attachment.
Whether you are a professional installer or a DIY enthusiast, this Horizontal Vent Kit provides a comprehensive solution for venting an approved appliance horizontally through the back of a suitable masonry chimney. Its quality construction and carefully selected components make it a reliable choice for your venting needs.
Choose the Horizontal DirectVent Pro Vent Kit 46DVA-HCL34 for a seamless and effective venting solution that meets the highest standards of performance and safety. Invest in the future of your appliance installations with confidence, knowing you have a top-tier venting solution at your disposal.
Applications:
Suitable for direct vent gas and propane stoves, heaters, and fireplaces, the kit meets the diverse needs of various heating appliances.
Clearances:
Follow the clearances specified by the appliance manufacturer to ensure safe and compliant installation.
Listings:
This Co-Linear Flex Kit is UL, CSA, or Warnock Hersey listed, assuring you of its compliance with industry standards for safety and quality.
Warranty:
Enjoy peace of mind with the limited-lifetime warranty, providing long-term protection and support for your investment.
Upgrade your masonry chimney with the DirectVent Pro 46DVA-HCL34 Co-Linear Flex Kit, combining functionality, durability, and ease of installation for a reliable direct vent solution.
Throughout North America, dormant masonry fireplaces are often repurposed or closed-off, finding new uses from practical to amusing. Urban areas face challenges like limited access to seasoned firewood or the prohibitive cost of firewood, leading to dormant fireplaces. Personal preferences, safety concerns, or overall system condition can also contribute to a fireplace lying dormant.
For new homeowners eager to rekindle the warmth of a fireplace, the solution lies in modern gas fireplace inserts. Gas inserts are not only convenient and safe but also efficient, providing a reliable source of backup heat during power outages.
In the past, financial constraints or issues with the fireplace's masonry chimney deterred homeowners from this option. However, DuraVent's innovative Horizontal Vent Kit offers a game-changing solution. This kit allows safe venting through the lower portion of an existing masonry chimney, even in cases where the top portion is missing or where traditional venting systems face obstacles.
Potential applications of this venting solution include heritage structures with limited venting options, homes with safety concerns due to steep roofs or over-height chimneys, and situations where typical vent installations are cost-prohibitive.
Horizontal venting is not a new concept, but DuraVent's kit is tailored for masonry fireplaces, providing flexibility and ease of installation. Approved by insert manufacturers, the Horizontal Vent Kit for DV Inserts includes two 10-foot lengths of 3-inch DuraFlex aluminum, offering ample material for the transition from vertical to horizontal.
Installation is straightforward and can be completed in a few hours. The installer marks the exterior wall for the termination hole, ensuring enough space for the flex to pass through. The flexible aluminum flex, with a 3” diameter, easily passes through the opening left by removing a standard brick. A weighted rope helps determine the approximate vent length, facilitating a smooth transition from vertical to horizontal.
With the kit, the installer attaches both lengths of flex to the appliance according to the OEM’s instructions and secures the termination to the exterior of the masonry chimney. The termination cap, flex lengths, and clamps are included in the kit, offering a turnkey solution. Prior to installation, ensure the vent kit is approved by the appliance manufacturer and follow the provided instructions for both the appliance and the vent kit. Revitalize your dormant fireplace with DuraVent's Horizontal Vent Kit, combining safety, efficiency, and ease of installation for a cozy and worry-free experience.
If you're considering the installation of a DirectVent Pro Chimney Liner System, it's crucial to follow specific precautions to ensure safety and compliance. This engineered product has been meticulously designed and tested for use with approved direct vent gas appliances, guaranteeing efficiency and reliability. Below are essential details and steps to guide you through a successful installation.
The DuraVent Direct Vent Chimney Liner System is a specialized product with strict installation guidelines. Deviating from these instructions may void the warranty and pose serious fire, health, or safety hazards. Key precautions include avoiding the installation of damaged components, unauthorized modifications, or the use of non-approved parts.
Before commencing the installation, ensure your safety with protective gear such as gloves and safety glasses. Exercise caution when working with ladders or on rooftops, and be aware of electrical wiring locations in walls and ceilings.
Careful planning is essential for a successful installation. The Direct Vent Chimney Liner System is designed for use in existing masonry or zero-clearance chimneys, providing flexibility for various direct vent gas appliances. Measure the required flex length, ensuring it reaches from the appliance outlet to the termination cap. Remember to maintain clearances to prevent fire hazards and comply with local building codes.
Follow these steps for a proper installation in a masonry or zero-clearance chimney:
Perform a semiannual inspection of the venting system, checking for corrosion, blockages, and evidence of excessive condensate. Regular maintenance ensures the system's longevity and efficient performance.
Q: Can I install the DirectVent Pro Chimney Liner System myself, or should I hire a professional installer?
A: While some homeowners may have the skills for a DIY installation, it's highly recommended to hire a professional installer. This ensures compliance with safety standards, local building codes, and proper handling of the specialized components to guarantee a safe and efficient installation.
Q: What safety precautions should I take during the installation process?
A: Safety is paramount. Always wear protective gear such as gloves and safety glasses. Exercise caution when working on ladders or rooftops, and be aware of electrical wiring locations in walls and ceilings to prevent accidents.
Q: Can the DirectVent Pro Chimney Liner System be used for all types of direct vent gas appliances?
A: Yes, the system is designed for use with approved direct vent gas appliances. However, it's crucial to check the compatibility with your specific appliance by referring to the manufacturer's guidelines and the DirectVent Pro Chimney Liner System Installation Guide.
Q: What are the key planning considerations for a successful installation?
A: Careful planning is essential. Measure the required flex length, ensuring it reaches from the appliance outlet to the termination cap. Consider clearances to prevent fire hazards and comply with local building codes. Detailed planning ensures a smooth installation process.
Q: How often should I perform maintenance on the DirectVent Pro Chimney Liner System?
A: Regular maintenance is crucial for the system's longevity and efficient performance. Perform a semiannual inspection for corrosion, blockages, and evidence of excessive condensate. Adhering to a maintenance schedule helps identify and address potential issues promptly.
Remember, these questions provide general guidance, and for specific details, always refer to the DirectVent Pro Chimney Liner System Installation Guide and the guidelines provided by your appliance manufacturer.
No posts found
Click on the Add New button below to submit a question about this product. Please ONLY submit product questions. For all other inquiries, please contact us at 1-888-986-1535.