DuraVent 8" x 24" DuraBlack Stainless Stove Pipe 8DBK-24SS
DuraBlack Single-Wall Stove Pipe Stainless Steel is a high-quality and versatile heating system component designed for use in wood-burning stoves, fireplaces, furnaces, boilers, and other heating appliances. This product is specifically engineered to handle the intense heat and demands of these heating systems while ensuring safety and efficiency.
It's important to note that DuraBlack Single-Wall Stove Pipe Stainless Steel is typically used as a connector between the appliance and the chimney or venting system. When installing this pipe, it's crucial to follow local building codes and manufacturer guidelines to ensure proper safety and performance.
Overall, DuraBlack Single-Wall Stove Pipe Stainless Steel is a reliable and durable solution for venting and connecting heating appliances, offering both functionality and aesthetics while meeting the demanding requirements of wood-burning stoves, fireplaces, and similar heating systems.
When it comes to connecting your wood stove to a chimney, you need a stovepipe that combines economy and reliability. DuraBlack® Stainless Steel, the single-wall interior stovepipe from DuraVent, is the perfect choice. Manufactured to meet DuraVent's rigorous standards, DuraBlack® Stainless Steel offers an economical, drip-free solution designed for longevity.
DuraBlack® Stainless Steel is crafted from robust 0.020-inch 430 stainless steel, renowned for its resistance to corrosion and heat. This ensures that your stovepipe can withstand the demanding conditions of wood stove heating while maintaining its structural integrity. The die-formed end fittings guarantee a secure, leak-free connection, providing you with peace of mind.
DuraBlack® Stainless Steel offers a range of diameters, including 6" to 8", making it suitable for various wood stove and chimney setups. This versatility allows you to find the perfect fit for your heating needs without compromising on quality.
Installing DuraBlack® Stainless Steel is a user-friendly process that doesn't require specialized tools or skills. Its adjustable lengths eliminate the need for cutting and crimping, saving you valuable time and effort. Here's a basic guide to installing DuraBlack® Stainless Steel:
Measurement: Carefully measure the distance from your wood stove to the chimney opening to determine the required length of DuraBlack® Stainless Steel stovepipe.
Assemble Sections: Join the male and female ends of the necessary sections of DuraBlack® Stainless Steel. Ensure a secure fit by utilizing the twist-lock mechanism.
Connect to Stove: Attach one end of the stovepipe to your wood stove's outlet, ensuring a snug fit.
Connect to Chimney: The opposite end of the stovepipe should connect to the chimney opening or adapter. Ensure it's securely in place.
Secure All Joints: To prevent leaks, make sure all joints are tightly sealed.
Safety Compliance: Always adhere to safety guidelines and local building codes when installing a wood stove and stovepipe.
Q. Is DuraBlack® Stainless Steel suitable for all types of wood stoves?
A: DuraBlack® Stainless Steel is designed specifically for connecting wood stoves to manufactured chimneys. Verify compatibility with your specific stove model.
Q: Can I use DuraBlack® Stainless Steel for other heating appliances like pellet stoves or gas stoves?
A: DuraBlack® Stainless Steel is intended for use with wood stoves. For other heating appliances, consult the manufacturer's guidelines and consider an appropriate venting solution.
Q: Do I need a professional installer for DuraBlack® Stainless Steel?
A: While DuraBlack® Stainless Steel installation is straightforward, it's advisable to have a professional installer ensure proper setup, especially if you are unfamiliar with stovepipe installation or local building codes.
Q: How long can I expect DuraBlack® Stainless Steel to last?
A: DuraBlack® Stainless Steel is designed for long-lasting durability. With proper maintenance and care, it can provide reliable service for many years.
Q: Can I paint DuraBlack® Stainless Steel to match my wood stove or interior decor?
A: DuraBlack® Stainless Steel has a natural stainless steel finish. If you wish to change its appearance, consult with a paint specialist to select an appropriate heat-resistant paint.
In conclusion, DuraBlack® Stainless Steel is your dependable choice for connecting your wood stove to a chimney. Its high-quality stainless steel construction, versatile sizing options, and easy installation process make it a cost-effective solution for heating your home with confidence. Whether you're a seasoned wood stove user or a novice, DuraBlack® Stainless Steel delivers the performance and durability you need for a warm and inviting living space.
While the terminology can often be a source of confusion, there are indeed differences between a chimney pipe and a stove pipe, commonly used in a home setting.
In summary, while these two types of pipes serve a similar function, their application, material, and design differentiate them. The stove pipe works inside, transitioning to the chimney pipe when the home's boundary is reached.
Often referred to by multiple names such as double-wall chimney pipe, triple-wall chimney pipe, all-fuel pipe, or insulated chimney pipe, Class A chimney pipe is primarily used to vent the high-temperature exhaust that results from burning wood, coal, or oil in various appliances. These appliances can include fireplaces, stoves, boilers and furnaces.
Although not every venting system needs a Class A pipe, this type of pipe is a strict requirement for all wood-burning fireplaces and stoves.
It is important to state that Class A chimney pipe is UL-listed. This certification allows its application across a wide range of vent pipes produced by various manufacturers as well as its use with a wide array of fireplaces, stoves, inserts, and furnaces.
However, caution has to be taken when using Class A chimney pipe. Mixing and using different brands of Class A chimney pipe within one chimney system is not advisable unless it is specifically permitted by the manufacturer. The reasoning behind this is that all brands of Class A pipes are engineered distinctly and should be used as a comprehensive system - from beginning to end.
To modify or enhance your existing chimney system, it's essential to identify your current Class A pipe's make and model. Ideally, you should buy a similarly typified unit. But suppose your existing pipe's make and model are from a phased-out or outdated brand. In that case, a complete reinstallation of your chimney system may be inevitable.
Evaluate the inclination of the roof. For instance, a 6/12 pitch denotes a vertical elevation of 6 inches over a horizontal stretch of 12 inches. Choose the flashing that is most relevant.
In compliance with the building codes, you need to calculate the lowest possible height of the chimney from the rooftop. These regulations demand that the chimney extends a minimum of 3 feet above the point where it penetrates the roof. Additionally, it must stand 2 feet taller than any part of a structure that exists within a 10-foot radius.
Check whether the installation procedure is for a 'through-the-roof' or a 'through-the-wall' setup. Additional parts like a Wall Thimble, Tee/Cap, Tee Support, and Wall Straps are necessary for a 'through-the-wall' deployment.
For optimal results, we recommend positioning the chimney inside the structure when feasible. A cold chimney exterior will lead to diminished draft and increased creosote production.
To steer clear of rafters or any obstructive items, you need to calculate two things - the needed horizontal distance and the accessible vertical height. There are two kinds of elbows accessible - 15° and 30°. However, please note that in the US, it's disallowed to use elbows that exceed 30°. To guarantee sufficient support, make use of elbow straps.
Calculate the total required lengths of both the chimney and stovepipe for the installation. If you're utilizing a 5”- 8” DuraTech pipe, deduct 1.25" per joint to get the installed length. For a pipe diameter lying between 10” and 24”, a deduction of 0.75" per joint is necessary. A reduction of 1.25" per DuraBlack stovepipe joint and 1.5" per DVL stovepipe joint must also be factored in.
The lowest acceptable height for a chimney located at sea level, assuming it's straight and vertical, should range from 10 to 15 feet above the appliance outlet. However, factors such as higher elevations, or the inclusion of junctions or a tee, will necessitate an increase of roughly 30% to 60% in the chimney's height. This is crucial to ensure an effective draft.
Ensure Fire Safety. Always keep a minimum of 2 inches distance from combustible materials. Adhere to your local construction regulations and arrange for a certified expert to carry out an inspection of your chimney.
You are required to use DVL/DuraBlack Chimney Adapter when you are linking DVL pipe to either a Ceiling Support Box or a Finishing Collar. In addition, when the connection involves DuraBlack pipe, it is mandatory to use a DVL/DuraBlack Chimney Adapter, a DuraBlack Slip Connector, or a Snap-Lock Adapter.
A Wall Thimble should be utilized in all instances where horizontal through-the-wall installations are carried out. It must be properly matched with a chimney pipe of an appropriate length. In instances where the walls are considerably thicker, the Wall Thimble's telescoping parts can be detached allowing the insertion of a custom-made extension.
It's mandatory to use an Attic Insulation Shield in all installations that penetrate through an attic, regardless of the attic's insulation status.
It is mandatory to utilize the Firestop Radiation Shield when a chimney traverses through a floor or ceiling without having a support box.
PDF Downloads:
Catalogs
Installation Instructions
FAQs
Bulletins
Brochures
Manufacturer's Warranty
DURAVENT LIMITED LIFETIME WARRANTY
DuraVent, Inc. (“DuraVent”) provides this limited lifetime warranty for all of its products with the exception of Ventinox® (lifetime), and PolyPro® (ten years). Subject to the limitations set forth below, DuraVent warrants that its products will be free from defects in material or manufacturing, if properly installed, maintained and used. DuraVent products are fully warranted if installed only by a professional installer. This Warranty is transferable from the original homeowner to the buyer of the home. This warranty does not cover normal wear and tear, smoke damage or damage caused by chimney fires, acts of God, or any product that was: (1) purchased other than from an authorized DuraVent dealer, retailer or distributor; (2) modified or altered; (3) improperly serviced, inspected or cleaned; or (4) subject to negligence or any use not in accordance with the installation instructions included with the product as determined by DuraVent. Installation instructions are available online at www.duravent.com under Support/Literature and through our Customer Service Department 800-835-4429 or [email protected]. This limited lifetime warranty applies only to parts manufactured by DuraVent.
DuraVent provides the following warranties for its products: One Hundred Percent (100%) MSRP 15 years from the date of purchase, and Fifty Percent (50%) thereafter, except for the following limitations on: all Termination Caps and DuraBlack® are warranted at One Hundred Percent (100%) for five years. All warranty obligations of DuraVent shall be limited to repair or replacement of the defective product pursuant to the terms and conditions applicable to each product line. These remedies shall constitute DuraVent’s sole obligation and sole remedy under this warranty. This warranty provides no cash surrender value. The terms and conditions of this warranty may not be modified, altered or waived by any action, inaction or representation, whether oral or in writing, except upon the express, written authority of an executive officer of DuraVent.
Corn, bio-fuels, driftwood or other wood containing salt, preservative-treated lumber, plastic and household trash or garbage, or wood pellets containing such materials must not be burned in the appliance or fireplace. In case of a chimney fire, the chimney must be inspected and approved by a certified Chimney Sweep before reuse. After each annual inspection, maintenance, and cleaning, the certified Chimney Sweep must fill out and date the appropriate section of the warranty card provided with the chimney liner.
LIMITATIONS ON INTERNET SALES:
Notwithstanding any other terms or conditions of this Limited Lifetime Warranty, DuraVent provides no warranty for the following specific products if such products are not installed by a qualified professional installer: DuraTech®, DuraPlus HTC®, DuraChimney® II, PelletVent Pro®, DirectVent Pro®, FasNSeal®, FasNSeal® W2, FasNSeal® Flex, and PolyPro®, and DuraVent’s relining products including DuraLiner®, DuraFlex® (SW, Pro, 316, 304), and Ventinox®. For purposes of this warranty, a trained professional installer is defined as one of the following: licensed contractors with prior chimney installation experience, CSIA Certified Chimney Sweeps, NFI Certified Specialists, or WETT Certified Professionals.
No posts found
Click on the Add New button below to submit a question about this product. Please ONLY submit product questions. For all other inquiries, please contact us at 1-888-986-1535.